COVERiT NovoProof®

Fixing DA-K

Bonded: Use Adhesive F in the field; Contact adhesive TA or suitable spray contact adhesive at connections. Mechanically fixed: Use approved fixings in the covered seam area. Select type and quantity for the substrate and wind-uplift design. Do not use Adhesive F on unfaced polystyrene, bare bituminous torch-on membranes or hot-applied bitumen coatings. Hot-air weld ThermoFast® seams, weldable under site conditions down to approx. −10 °C; carry out trial welds first. Rolls come with a ThermoFast® joining edge along the long side. Also for balconies and terraces.